Study of new test method for evaluation of fire propagation along façade wall with exterior thermal insulation

Hideki Yoshioka, Hsin Chieh Yang, Masamichi Tamura, Masashi Yoshida, Takafumi Noguchi, Manabu Kanematsu, Kouji Koura, Yasuji Ouaki

研究成果: Article査読

抄録

With regard to fire protection for exterior walls of a building, only 'fire-resistive performance 'is considered, according to the current building standard law of japanAnd fire propagation along combustible material installed at external side of fire-resistive wall is not specifically evaluated, even though cambustion of extenal cladding could cause acceleration of the fire propagation extierior walls in some cases. In this study, new test method for evaluation of fire propagation combustible cladding, was proposed and also test specimens produced referring to façade wall with exterior thermal insulation were burned in order that the application of the method is demonstrated.

本文言語English
ページ(範囲)537-542
ページ数6
ジャーナルAIJ Journal of Technology and Design
17
36
DOI
出版ステータスPublished - 6月 2011