Abstract
This study focused on the efficient use of cross-ventilation in a densely populated area. Wind tunnel experiments were conducted to understand the relation between the building coverage ratio and the wind pressure coefficient. The experiments and calculations revealed the following information: (1) the overall Cp value of a flat roof residence approaches zero when the building coverage ratio increases; (2) a negative pressure is maintained near the ridge of a leeward roof; and (3) the efficient use of the negative pressure near the ridge on the leeward roof can improve the cross-ventilation rate in a densely populated area.
Original language | English |
---|---|
Pages (from-to) | 951-956 |
Number of pages | 6 |
Journal | Journal of Environmental Engineering |
Volume | 74 |
Issue number | 642 |
DOIs | |
Publication status | Published - Aug 2009 |
Keywords
- Building Coverage Ratio
- Cross-Ventilation
- Local Dynamic Similarity
- Wind Pressure Coefficient Ventilation Flow Rate
- Wind Tunnel Experiments