Abstract
Short-term allowable shear force of RC multi-story walls for safety assurance and damage control was specified in AIJ standard. However, this allowable force for multi-story shear walls with door openings was defined by limited data. In this study, based on the experimental results of five 1/4 scale multi-story shear wall specimens with various disposition of vertically aligned door openings, several strength reduction factors related to door openings were verified for the short-term allowable force based on the observed strengths for safety assurance and the observed residual crack widths for damage control. Consequently, an optimal reduction factor was suggested.
Translated title of the contribution | VERIFICATION OF STRENGTH REDUCTION FACTOR RELATED TO OPENING HEIGHT OF RC MUTLI-STORY SHEAR WALLS FOR THE SHORT-TERM ALLOWABLE SHEAR DESIGN - For Vertically Aligned Door Openings |
---|---|
Original language | Japanese |
Pages (from-to) | 621-632 |
Number of pages | 12 |
Journal | Journal of Structural and Construction Engineering |
Volume | 88 |
Issue number | 806 |
DOIs | |
Publication status | Published - Apr 2023 |