PVT・ヒートポンプ暖冷房換気給湯システム搭載住宅のエネルギー自立率向上に関する研究

Translated title of the contribution: RESEARCH ON IMPROVING THE ENERGY INDEPENDENCE RATE OF HOMES EQUIPPED WITH PVT AND HEAT PUMP HEATING / COOLING / VENTILATION / WATER HEATING SYSTEMS

Yuto Takahashi, Tomoya Amano, Masayuki Mae, Kozo Takase, Makoto Satoh, Hyunwoo Roh

Research output: Contribution to journalArticlepeer-review

Abstract

In recent years, there has been a demand for energy conservation in housing. The authors study PVT/heat pump heating/cooling/ventilation/ water heating system to improve the energy independence rate in winter. They conducted case studies to verify the results of the analysis, which suggested that the energy independence rate can be improved by raising the temperature setting during the daytime and using PV power generation to store heat under the floor. The analysis results showed that appropriate heat pump heating operation and under-floor heat storage design tended to improve the energy independence rate and realize a comfortable thermal environment.

Translated title of the contributionRESEARCH ON IMPROVING THE ENERGY INDEPENDENCE RATE OF HOMES EQUIPPED WITH PVT AND HEAT PUMP HEATING / COOLING / VENTILATION / WATER HEATING SYSTEMS
Original languageJapanese
Pages (from-to)1380-1385
Number of pages6
JournalAIJ Journal of Technology and Design
Volume30
Issue number76
DOIs
Publication statusPublished - Oct 2024

Fingerprint

Dive into the research topics of 'RESEARCH ON IMPROVING THE ENERGY INDEPENDENCE RATE OF HOMES EQUIPPED WITH PVT AND HEAT PUMP HEATING / COOLING / VENTILATION / WATER HEATING SYSTEMS'. Together they form a unique fingerprint.