T1 - Environmental Impact Assessment of PEM Fuel Cell Combined Heat and Power Generation System for Residential Application Considering Cathode Catalyst Layer Degradation
AU - Tochigi, Shota
AU - Dowaki, Kiyoshi
N1 - Publisher Copyright:
© 2023 by the authors.
PY - 2023/2
Y1 - 2023/2
N2 - Recently, fuel cell combined heat and power systems (FC-CGSs) for residential applications have received increasing attention. The International Electrotechnical Commission has issued a technical specification (TS 62282-9-101) for environmental impact assessment procedures of FC-CGSs based on the life cycle assessment, which considers global warming during the utilization stage and abiotic depletion during the manufacturing stage. In proton exchange membrane fuel cells (PEMFCs), platinum (Pt) used in the catalyst layer is a major contributor to abiotic depletion, and Pt loading affects power generation performance. In the present study, based on TS 62282-9-101, we evaluated the environmental impact of a 700 W scale PEMFC-CGS considering cathode catalyst degradation. Through Pt dissolution and Ostwald ripening modeling, the electrochemical surface area transition of the Pt catalyst was calculated. As a result of the 10-year evaluation, the daily power generation of the PEMFC-CGS decreased by 11% to 26%, and the annual global warming value increased by 5% due to the increased use of grid electricity. In addition, when Pt loading was varied between 0.2 mg/cm2 and 0.4 mg/cm2, the 10-year global warming values were reduced by 6.5% to 7.8% compared to the case without a FC-CGS.
AB - Recently, fuel cell combined heat and power systems (FC-CGSs) for residential applications have received increasing attention. The International Electrotechnical Commission has issued a technical specification (TS 62282-9-101) for environmental impact assessment procedures of FC-CGSs based on the life cycle assessment, which considers global warming during the utilization stage and abiotic depletion during the manufacturing stage. In proton exchange membrane fuel cells (PEMFCs), platinum (Pt) used in the catalyst layer is a major contributor to abiotic depletion, and Pt loading affects power generation performance. In the present study, based on TS 62282-9-101, we evaluated the environmental impact of a 700 W scale PEMFC-CGS considering cathode catalyst degradation. Through Pt dissolution and Ostwald ripening modeling, the electrochemical surface area transition of the Pt catalyst was calculated. As a result of the 10-year evaluation, the daily power generation of the PEMFC-CGS decreased by 11% to 26%, and the annual global warming value increased by 5% due to the increased use of grid electricity. In addition, when Pt loading was varied between 0.2 mg/cm2 and 0.4 mg/cm2, the 10-year global warming values were reduced by 6.5% to 7.8% compared to the case without a FC-CGS.
KW - Life cycle thinking
KW - Pt loading
KW - abiotic depletion value
KW - catalyst layer degradation
KW - environmental impact assessment
KW - global warming value
KW - power generation performance
KW - proton exchange membrane fuel cell
KW - residential application
KW - stationary fuel cell
UR - http://www.scopus.com/inward/record.url?scp=85149185918&partnerID=8YFLogxK
U2 - 10.3390/en16041985
DO - 10.3390/en16041985
M3 - Article
AN - SCOPUS:85149185918
SN - 1996-1073
VL - 16
JO - Energies
JF - Energies
IS - 4
M1 - 1985