Abstract

The quantification of serum/plasma estradiol (E2) is useful for the diagnosis, pathological analysis, and monitoring of the therapeutic efficacy of estrogen-dependent diseases. In this study, an improved derivatization method using 1-(2,4-dinitro-5-fluorophenyl)-4,4-dimethylpiperazinium iodide (MPDNP-F) was developed and combined with liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) for the sensitive and specific quantification of the serum/plasma E2. In the new method, the reaction time was reduced to 15 min from 90 min (two-step reaction in the previous method) by the direct reaction of MPDNP-F with E2 at 60°C in the presence of 4-dimethylaminopyridine (DMAP). DMAP served as the organic catalyst and had a less negative effect on the LC/ESI-MS/MS instrument compared to the non-volatile inorganic salt (NaHCO3), which was used in the previous method. The collision-induced dissociation of the molecular cation ([M]+) of the resulting derivative provided a product ion containing the E2-skeleton ([M–NO2–H]+), which significantly enhanced the assay sensitivity and specificity; compared to the dansyl chloride derivatization, which is the currently most-used derivatization procedure for the LC/ESI-MS/MS assays of E2, the MPDNP-F derivatization had significantly fewer interfering peaks and a clear and flat baseline in the serum sample analysis. The MPDNP-F derivatization–LC/ESI-MS/MS method enabled the precise and accurate quantification of E2 even at a 5.0 pg/mL concentration (lower limit of quantification) with a small sample volume (100 μL of serum/plasma) and had a tolerance for the matrix effect. This method was also proven to serve as a more sensitive and specific alternative to the clinically used chemiluminescence enzyme immunoassay. Graphical Abstract: [Figure not available: see fulltext.]

Original languageEnglish
Pages (from-to)597-608
Number of pages12
JournalAnalytical and bioanalytical chemistry
Volume416
Issue number2
DOIs
Publication statusPublished - Jan 2024

Keywords

  • Derivatization
  • Estradiol
  • LC/ESI-MS/MS
  • Serum/plasma
  • Skeleton-containing product ion

Fingerprint

Dive into the research topics of 'Derivatization procedure of estradiol with a combination of MPDNP-F and 4-dimethylaminopyridine to generate product ion containing estradiol-skeleton for reliable determination of its serum/plasma concentrations by LC/ESI-MS/MS'. Together they form a unique fingerprint.

Cite this