Skip to main navigation Skip to search Skip to main content

Calculation of Degradation Rates of PV Modules Using Outdoor Measured I-V Curves and Multi Reference Linear Interpolation/Extrapolation Method

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Outdoor degradation rates (DR) of PV modules for ten years were calculated by means of multi reference linear interpolation/extrapolation method (MRLIM), which utilizes many outdoor measured I-V curve data. Transitions of monthly translated I-V curves under the STC, which are created by MRLIM, indicates how PV module degrades. The DR of maximum power (Pm), short circuit current, open circuit voltage, fill factor, and series resistance were calculated from translated I-V curves. As a result, a poly crystalline Si case, annual DR of Pm was calculated as -0.53 %/year. In addition, the accuracy of this method was calculated by comparing with indoor measurement results.

Original languageEnglish
Title of host publication2019 IEEE 46th Photovoltaic Specialists Conference, PVSC 2019
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages855-860
Number of pages6
ISBN (Electronic)9781728104942
DOIs
Publication statusPublished - Jun 2019
Event46th IEEE Photovoltaic Specialists Conference, PVSC 2019 - Chicago, United States
Duration: 16 Jun 201921 Jun 2019

Publication series

NameConference Record of the IEEE Photovoltaic Specialists Conference
ISSN (Print)0160-8371

Conference

Conference46th IEEE Photovoltaic Specialists Conference, PVSC 2019
Country/TerritoryUnited States
CityChicago
Period16/06/1921/06/19

Fingerprint

Dive into the research topics of 'Calculation of Degradation Rates of PV Modules Using Outdoor Measured I-V Curves and Multi Reference Linear Interpolation/Extrapolation Method'. Together they form a unique fingerprint.

Cite this