Additional verification of strength reduction factor related to opening height of RC shear walls and assurance DESIGN for predominant flexural yielding

Hong Liu, Yasushi Sanada, Rokhyun Yoon, Toshikatsu Ichinose, Shu Izaki, Koichi Kato, Fumio Kusuhara, Suguru Suzuki, Susumu Takahashi

Research output: Contribution to journalArticlepeer-review

Abstract

Focusing on a strength reduction factor related to door openings provided in AIJ standards in 2010, a series of experimental studies was performed with multi-story shear wall specimens with different configurations of door openings. In this study, besides the former specimen with eccentricallyaligned door openings, two specimens were designed to fail between the door openings. The observed strengths of all specimens agreed well with the values predicted using the index proposed by the authors' previous study. Furthermore, a specimen with shear margin of 1.2 obtained using the proposed index was tested, and its effectiveness for the assurance design was verified.

Original languageEnglish
Pages (from-to)267-277
Number of pages11
JournalJournal of Structural and Construction Engineering
Volume86
Issue number780
DOIs
Publication statusPublished - 2021

Keywords

  • Flexure yielding
  • Multi-story shear walls with openings
  • Opening height
  • Reduction factor for opening
  • Shear failure
  • Ultimate strength

Fingerprint

Dive into the research topics of 'Additional verification of strength reduction factor related to opening height of RC shear walls and assurance DESIGN for predominant flexural yielding'. Together they form a unique fingerprint.