T1 - A system analysis of cold storage using the new non-freon refrigerant “GF-08”
AU - Kataniwa, Shun
AU - Dowaki, Kiyoshi
N1 - Publisher Copyright:
Copyright © 2020, AIDIC Servizi S.r.l.
PY - 2020
Y1 - 2020
N2 - The equipment for chilling or freezing food consumes much energy. Therefore, there is a need to reduce the energy consumption. Also, to contribute to reduce the greenhouse gas (GHG) emissions, it is necessary to replace conventional refrigerants which affect Global Warming because of high Global Warming Potential (GWP). Hence, there is a need for the use of alternative refrigerants with lower GWPs. Therefore, in this study, the potential of the non-freon refrigerant GF-08, which consists of hydro-carbons, as an alternative refrigerant was evaluated. The use of GF-08 for chilling and freezing storage systems was evaluated. The eco-benefits of GF-08 in comparison to the conventional refrigerant (R404A) was evaluated by developing a theoretical simulation model. A demo-test using a refrigerator in a restaurant was conducted to validate the simulated result. This result showed that performance differences depend on different operating conditions of temperature. Based on the simulation model, the benefits considering the energy reduction was evaluated. The reduction of the annual energy consumption, and the environmental impact of GF-08 using the life cycle assessment (LCA) methodology were estimated. The use of GF-08 reduced the annual energy consumption by 28.6% and the GHG emissions by 27.1 % in comparison to the R404A.
AB - The equipment for chilling or freezing food consumes much energy. Therefore, there is a need to reduce the energy consumption. Also, to contribute to reduce the greenhouse gas (GHG) emissions, it is necessary to replace conventional refrigerants which affect Global Warming because of high Global Warming Potential (GWP). Hence, there is a need for the use of alternative refrigerants with lower GWPs. Therefore, in this study, the potential of the non-freon refrigerant GF-08, which consists of hydro-carbons, as an alternative refrigerant was evaluated. The use of GF-08 for chilling and freezing storage systems was evaluated. The eco-benefits of GF-08 in comparison to the conventional refrigerant (R404A) was evaluated by developing a theoretical simulation model. A demo-test using a refrigerator in a restaurant was conducted to validate the simulated result. This result showed that performance differences depend on different operating conditions of temperature. Based on the simulation model, the benefits considering the energy reduction was evaluated. The reduction of the annual energy consumption, and the environmental impact of GF-08 using the life cycle assessment (LCA) methodology were estimated. The use of GF-08 reduced the annual energy consumption by 28.6% and the GHG emissions by 27.1 % in comparison to the R404A.
UR - http://www.scopus.com/inward/record.url?scp=85082763760&partnerID=8YFLogxK
U2 - 10.3303/CET2078032
DO - 10.3303/CET2078032
M3 - Article
AN - SCOPUS:85082763760
SN - 1974-9791
VL - 78
SP - 187
EP - 192
JO - Chemical Engineering Transactions
JF - Chemical Engineering Transactions
ER -