剛性付加機能を有するオイルダンパーの開発および構造的特性に関する実験的研究

Translated title of the contribution: DEVELOPMENT OF THE OIL DAMPER WITH STIFFNESS FOR ARCHITECTURAL VIBRATION CONTROL AND EXPERIMENTAL RESEARCH ON STRUCTURAL CHARACTERIZATION

Atsuki Yokoyama, Osamu Takahashi

Research output: Contribution to journalArticlepeer-review

Abstract

This paper indicates test and analysis results of the new oil damper, “Oil Damper with Stiffness”. It was developed to solve some issues about seismic retrofit. There are difficulties to reinforce buildings which are designed by the Old Buildings Standards Act before 1981. Especially, factory and warehouse buildings have low stiffness. Therefore, it is prevailing to retrofit old building using braces and oil dampers, but this way requires many reinforced areas. This paper also indicates the analysis model of the damper and effectiveness from the results of time history response analysis using a S.D.O.F. model.

Translated title of the contributionDEVELOPMENT OF THE OIL DAMPER WITH STIFFNESS FOR ARCHITECTURAL VIBRATION CONTROL AND EXPERIMENTAL RESEARCH ON STRUCTURAL CHARACTERIZATION
Original languageJapanese
Pages (from-to)954-965
Number of pages12
JournalJournal of Structural and Construction Engineering
Volume87
Issue number800
DOIs
Publication statusPublished - 2022

Fingerprint

Dive into the research topics of 'DEVELOPMENT OF THE OIL DAMPER WITH STIFFNESS FOR ARCHITECTURAL VIBRATION CONTROL AND EXPERIMENTAL RESEARCH ON STRUCTURAL CHARACTERIZATION'. Together they form a unique fingerprint.

Cite this